Water Solution – One Call Ahead
Water Solution – One Call Ahead
Enquire? Send Your Mail
As a leading Ultrafiltration (UF) Plant manufacturer in India, Ultra filtration is a membrane-based technology, which is used for separation of higher molecular weight particles from water. It can separate particles of even 0.02 microns from. Different membrane configurations and sizes are available for filtration requirements. Hollow Fiber and Spiral wound configurations are most commonly used in the industry. Unlike RO membranes, the UF membranes have tolerance for free chlorine also they do not alter minerals compositions.
Ultra filtration system can be used both in pre-treatment and post treatment process. The best Feature of UF Plant is Simple to operate, easy to maintain, Automatic operation, Compact, Adequate safety interlocks, Automatic forward flush and back flush.
We offer both customized and standardized skid mounted UF Plant.
Robust Pre & Post Treatment: Ideal as a standalone system or as a pre-treatment to protect expensive RO membranes from fouling.


Free site visit & custom proposal from our engineers within 48 hours. ISO 9001:2015 certified. 158+ projects delivered across India.
An Ultrafiltration (UF) Plant is a membrane-based water treatment system that removes particles as small as 0.02 microns from water — including bacteria, viruses, colloids, and high-molecular-weight organics. Unlike RO, UF membranes do not alter the mineral composition of water.
UF membranes (pore size ~0.01–0.1 micron) remove bacteria, viruses, and suspended particles but do not remove dissolved salts. RO membranes remove virtually everything including dissolved salts and minerals. UF is typically used as pre-treatment to protect RO membranes from fouling.
UF Plants are used for drinking water production, pre-treatment before RO systems, wastewater reclamation and reuse, food and beverage processing, pharmaceutical water treatment, and as a polishing step in ETP/STP effluent treatment.
UF membranes require regular automatic forward flush and backflush cycles (typically every 20–30 minutes). Chemical Enhanced Backwash (CEB) and Clean-In-Place (CIP) protocols are performed periodically. Proper pre-treatment extends membrane life to 5–7 years.
Yes. UF membranes with a pore size of 0.02 microns can achieve 4-log (99.99%) removal of bacteria and 2–4 log reduction of viruses. Combined with UV disinfection, UF + UV provides comprehensive microbiological protection.
UF Plants are available in Hollow Fiber configuration (most common — high packing density, easy backwashing) and Spiral Wound configuration (for specific industrial applications). Optima Water offers skid-mounted, modular UF plants in both configurations.
Free site visit and assessment by our engineers. 158+ projects delivered across India.