Water Solution – One Call Ahead
Water Solution – One Call Ahead
Enquire? Send Your Mail
Optima Water Solutions is an RO Plant Manufacturer in Delhi NCR. We manufacture and supply Industrial RO Plants for drinking water purification, process water treatment, boiler feed, and effluent recycling. ISO 9001:2015 certified with 12+ years of experience, we deliver energy-efficient Industrial RO Plant systems with full installation, commissioning, and AMC support across Delhi NCR and Delhi.
An Industrial RO Plant uses Reverse Osmosis membranes under high pressure to remove dissolved salts, heavy metals, bacteria, viruses, and organic compounds from water — producing high-purity permeate water with rejection rates of 95–99%.
Industrial RO systems are used when standard filtration is insufficient — particularly for high-TDS groundwater (above 1,000 ppm), brackish water, and process water requiring low conductivity. Key components include a high-pressure pump, RO membranes (spiral wound or hollow fibre), pressure vessels, antiscalant dosing, and CIP (Clean-In-Place) systems.
Modern industrial RO plants incorporate energy recovery devices and variable frequency drives (VFDs) to reduce power consumption by 30–40% compared to older designs.
NCR's RO Plant demand splits between two very different buyers: industrial units in Wazirpur, Okhla, IMT Manesar, and Udyog Vihar needing process water and boiler feed treatment, and residential and commercial buildings needing drinking water purification for borewell or municipal supply that varies significantly in hardness and TDS across different pockets of the region.
A meaningful share of our NCR industrial RO enquiries come from units that need consistent, low-TDS water for a specific process — electronics assembly, pharmaceutical packaging, and food processing all have tighter input-water specifications than general manufacturing, and the RO plant has to be sized and configured around that specification, not just a generic purification target.
Groundwater across parts of NCR, particularly in areas relying on borewell supply, tends to run harder and higher in dissolved solids than municipal Yamuna-sourced water, which is one of the more common reasons a Gurgaon or Faridabad facility ends up needing RO treatment even for what looks like a straightforward drinking water application.
Key industrial areas we serve in Delhi NCR:
For NCR industrial clients, we start by identifying the actual water quality requirement for the specific process — boiler feed water needs different treatment than process rinse water in electronics assembly, and drinking water purification for a residential society has a different target again. Sizing an RO plant around the wrong spec is the most common mistake we see in enquiries that come to us after an earlier, undersized system failed.
For sites relying on borewell water specifically, common across parts of Gurgaon, Faridabad, and the outer NCR belt, we typically recommend a pre-treatment stage — usually a softener or multimedia filter — ahead of the RO membranes themselves, since higher hardness and iron content in borewell water shortens membrane life significantly if it isn't addressed first.
Full water analysis — TDS, hardness, iron, SDI, conductivity. Membrane selection based on real data.
Hydraulic design, pressure calculations, membrane array layout, antiscalant programme selection.
In-house assembled and factory-tested before dispatch. Membrane integrity tested at factory.
Installation, pipe connections, electrical, controls. Full performance test with output water quality certificate.
Drinking Water
Boiler Feed
Pharmaceutical
Food & Beverage
Textile Dyeing
Electronics/Semiconductors
Effluent Recycling
Cooling Tower Makeup
Get a free site visit and custom proposal from our engineers within 48 hours. ISO 9001:2015 certified. 158+ projects delivered across India.
Often yes. Borewell water in parts of Gurgaon, Faridabad, and outer NCR tends to be harder and carry more dissolved iron than municipal supply, which can shorten RO membrane life if not pre-treated. We assess your specific water source before finalising a design.
This depends entirely on your process — boiler feed, rinse water, and drinking water purification all have different flow and quality requirements. Capacity for our NCR industrial clients typically ranges from 500 LPH to 2 MLD depending on the specific application.
Cost depends on capacity, feed water quality, and required pre-treatment. Systems typically range from ₹1.5 Lakh for smaller units to over ₹80 Lakh for larger industrial installations needing extensive pre-treatment. Call +91 9711880791 for an assessment specific to your water source.
Yes, our Delhi-based team covers Gurgaon, Noida, Faridabad, and Manesar directly, so AMC callouts and membrane replacement typically get a same-day or next-day response.
This depends heavily on your feed water quality and whether adequate pre-treatment is in place — properly pre-treated systems can run membranes for 2-3 years, while systems without pre-treatment on hard borewell water may need replacement much sooner. We size pre-treatment specifically to extend membrane life.
Our engineers in Delhi NCR are available for a free site visit and assessment.